Great Lakes Forklift Battery

Forklift Battery Chargers

Battery Charger Prices & Specs

Model Number

BB80-1-06-0510
BB80-1-06-0600
BB80-1-12-0510
BB80-1-12-0600
BB80-1-12-0750
BB80-1-12-0875
BB80-1-18-0600
BB80-1-18-0750
BB80-1-24-0475
BB80-3-12-0540
BB80-3-12-0750
BB80-3-12-0875
BB80-3-12-1050
BB80-3-18-0540
BB80-3-18-0750
BB80-3-18-0875
BB80-3-18-0965
BB80-3-18-1050
BB80-3-18-1260
BB80-3-24-0475
BB80-3-24-0600
BB80-3-24-0750
BB80-3-24-0875
BB80-3-24-1050

Price

$1,406
$1,479
$1,701
$1,615
$1,803
$1,989
$1,858
$1,957
$1,963
$2,265
$2,319
$2,404
$2,540
$2,404
$2,463
$2,531
$2,724
$2,788
$2,788
$2,278
$2,364
$2,528
$2,765
$2,861

Cell (voltage)

6 (12V)
6 (12V)
12 (24V)
12 (24V)
12 (24V)
12 (24V)
18 (36V)
18 (36V)
24 (48V)
12 (24V)
12 (24V)
12 (24V)
12 (24V)
18 (36V)
18 (36V)
18 (36V)
18 (36V)
18 (36V)
18 (36V)
24 (48V)
24 (48V)
24 (48V)
24 (48V)
24 (48V)

AMP Hour

380-510
511-600
380-510
511-600
601-750
751-875
510-600
601-750
380-475
475-540
541-750
751-875
876-1050
476-540
541-750
751-875
876-965
966-1050
1051-1260
380-475
475-600
600-750
751-865
966-1050

Please call for current pricing and product details.

Forklift Battery Chargers Michigan Ohio Chicago

Features include:

  • Fully integrated microprocessor control for automatic dv/dt di/dt termination
  • Interface jack for remote control and monitoring options
  • Automatic refresh charge every twelve hours
  • Charge time of eight hours or less on a normally discharged battery
  • Auto start with five second delay
  • Selectable delayed start from one to nine hours
  • Battery protection with override timers, wrong battery sensing and negative charge slope termination
Automatic shutdown for the following conditions
  • 80% charge does not occur in nine hours or;
  • Final charge is not reached six hours after 80% (gassing point)
  • Volts per cell are too high or too low
  • Charging current is too low
  • Battery cable is disconnected while charging
Automatic shutdown for the following conditions
  • 80% charge does not occur in nine hours or;
  • Final charge is not reached six hours after 80% (gassing point)
  • Volts per cell are too high or too low
  • Charging current is too low
  • Battery cable is disconnected while charging
  • Ferroresonant tapered charge for optimum battery and charger life
  • Selectable 80% voltage of 2.37 or 2.45 volts

Four position digital display for showing;

  • Charge current
  • Equalize in process
  • Fault diagnostics

Four LED indicators showing charge status including:

  • Charging
  • 80% Charged
  • Charge Complete
  • Fault Shutdown
  • Red push button for manual shutdown
  • Manual jump start for over-discharged batteries
  • Manual and or Automatic equalization
  • Ten foot long output cables for added flexibility
  • Numerous Output connectors available as standard

Product Safety

  • UL Listed
  • UL Listed to Canadian Safety Standards

Optional Features

  • Wall Mount brackets available
  • Remote Control Box available
  • Fungus protection available

.

Give us a call today and you’ll see why businesses in over 42 states have trusted us with their battery business!